I am running Intel Rapid Storage Technology version 11.7.0.1013
I have the following arrays and volumes defined:
Array, name: SATA_Array_0000
Volume, name: System, type: RAID 1
Disk 1, present, size 1TB
Disk 2, missing
Array, name: SATA_Array_0001
Volume, name: Media, type: RAID 1
Disk 1, present, size 2TB
Disk 2, missing
When I insert the missing 2TB disk, Intel RST automatically assigns it to the System volume and starts rebuilding it. I never have the opportunity to specify that it is the Media volume that is to be rebuild.
I cannot remove the 2TB disk from the System volume (where it does NOT belong) and assign it to the Media volume (where it DOES belong).
Ugh....
Here are some more gory detials:
System Report
System Information
OS name: Microsoft Windows 7 Professional
OS version: 6.1.7601 Service Pack 1 7601
System name: HOMESRV3
System manufacturer: Supermicro
System model: X8SAX
Processor: GenuineIntel Intel64 Family 6 Model 26 Stepping 5 2.668 GHz
BIOS: American Megatrends Inc., 1.0c
Intel® Rapid Storage Technology enterprise Information
Kit installed: 11.7.0.1013
User interface version: 11.7.0.1013
Language: English (United States)
RAID option ROM version: 8.9.1.1002
Driver version: 11.7.0.1013
ISDI version: 11.7.0.1013
Storage System Information
RAID Configuration
Array Name: SATA_Array_0000
Size: 1,907,739 MB
Available space: 3 MB
Number of volumes: 1
Volume member: System
Number of array disks: 2
Array disk: 5YD32SDR
Array disk: 6VPGQJQ0
Disk data cache: Enabled
Array Name: SATA_Array_0001
Size: 3,815,457 MB
Available space: 3 MB
Number of volumes: 1
Volume member: Media
Number of array disks: 2
Array disk: 5YD357GH
Array disk: 5YD340K9:1
Disk data cache: Enabled
Volume name: System
Status: Normal
Type: RAID 1
Size: 953,867 MB
System volume: Yes
Data stripe size: 64 KB
Write-back cache: Disabled
Initialized: Yes
Parity errors: 54
Blocks with media errors: 0
Physical sector size: 512 Bytes
Logical sector size: 512 Bytes
Volume name: Media
Status: Degraded
Type: RAID 1
Size: 1,907,726 MB
System volume: No
Data stripe size: 64 KB
Write-back cache: Disabled
Initialized: Yes
Parity errors: 0
Blocks with media errors: 0
Physical sector size: 512 Bytes
Logical sector size: 512 Bytes
Hardware Information
Controller name: Intel(R) Desktop/Workstation/Server Express Chipset SATA RAID Controller
Type: SATA
Mode: RAID
Number of SATA ports: 6
Number of volumes: 2
Volume: System
Volume: Media
Number of spares: 0
Number of available disks: 0
Rebuild on Hot Plug: Disabled
Manufacturer: 32902
Model number: 10274
Product revision: 0
Direct attached disk: 5YD32SDR
Direct attached disk: 6VPGQJQ0
Direct attached disk: 5YD357GH
Direct attached disk: 5YD340K9:1
Disk on Controller 0, Port 1
Status: Normal
Type: SATA disk
Location type: Internal
Usage: Array disk
Size: 1,863 GB
System disk: No
Disk data cache: Enabled
Command queuing: NCQ
SATA transfer rate: 3 Gb/s
Model: ST2000DL003-9VT166
Serial number: 5YD32SDR
SCSI device ID: 1
Firmware: CC32
Physical sector size: 512 Bytes
Logical sector size: 512 Bytes
Disk on Controller 0, Port 2
Status: Normal
Type: SATA disk
Location type: Internal
Usage: Array disk
Size: 932 GB
System disk: No
Disk data cache: Enabled
Command queuing: NCQ
SATA transfer rate: 3 Gb/s
Model: ST31000524AS
Serial number: 6VPGQJQ0
SCSI device ID: 2
Firmware: JC4B
Physical sector size: 512 Bytes
Logical sector size: 512 Bytes
Disk on Controller 0, Port 4
Status: Normal
Type: SATA disk
Location type: Internal
Usage: Array disk
Size: 1,863 GB
System disk: No
Disk data cache: Enabled
Command queuing: NCQ
SATA transfer rate: 3 Gb/s
Model: ST2000DL003-9VT166
Serial number: 5YD357GH
SCSI device ID: 4
Firmware: CC32
Physical sector size: 512 Bytes
Logical sector size: 512 Bytes
Disk on Controller 255, Port Unknown
Status: Missing
Type: Unknown disk
Location type: Unknown
Usage: Array disk
Size: 0 GB
System disk: No
Disk data cache: Enabled
Command queuing: None
SATA transfer rate: Unknown Gb/s
Model:
Serial number: 5YD340K9:1
SCSI device ID: 255
Firmware:
Physical sector size: 0 Bytes
Logical sector size: 0 Bytes
ATAPI device on Controller 0, Port 0
Location type: Internal
SATA transfer rate: 1.5 Gb/s
Model: Optiarc DVD RW AD-7241S
Serial number: Not Available
Firmware: 1.03
Empty port
Port: 3
Port location: Internal
Empty port
Port: 5
Port location: Internal