Intel Matrix Storage Manager - Rebuild Failed

$
0
0

Have a HP computer that had a hard drive fail.  The RAID worked and the system continued functioning.  We replaced the hard drive with the same model as the original.  Tried to rebuild the drive, but the rebuild fails to start.  Can't find any reason why the rebuild fails.

 

Below is the diagnostics information from Intel(R) Matrix Storage Manager.

 

 

System Information

 

Kit Installed: 8.9.0.1023

Kit Install History: 8.9.0.1023, Uninstall

Shell Version: 8.9.0.1023

 

OS Name: Microsoft Windows XP Professional

OS Version: 5.1.2600 Service Pack 3 Build 2600

System Name: USPHL-WS2

System Manufacturer: Hewlett-Packard

System Model: 3031h

Processor: Intel Pentium III Xeon processor ~2327 MHz

BIOS Version/Date: Hewlett-Packard 786G1 v01.22, 08/25/2009

 

Language: ENU

 

 

 

Intel(R) Matrix Storage Manager

 

Intel RAID Controller: Intel(R) ICH8R/ICH9R/ICH10R/DO/PCH SATA RAID Controller

Number of Serial ATA ports: 4

 

RAID Option ROM Version: 8.5.0.1030

Driver Version: 8.9.0.1023

RAID Plug-In Version: 8.9.0.1023

Language Resource Version of the RAID Plug-In: 8.9.0.1023

Create Volume Wizard Version: 8.9.0.1023

Language Resource Version of the Create Volume Wizard: 8.9.0.1023

Create Volume from Existing Hard Drive Wizard Version: 8.9.0.1023

Language Resource Version of the Create Volume from Existing Hard Drive Wizard: 8.9.0.1023

Modify Volume Wizard Version: 8.9.0.1023

Language Resource Version of the Modify Volume Wizard: 8.9.0.1023

Delete Volume Wizard Version: 8.9.0.1023

Language Resource Version of the Delete Volume Wizard: 8.9.0.1023

ISDI Library Version: 8.9.0.1023

Event Monitor User Notification Tool Version: 8.9.0.1023

Language Resource Version of the Event Monitor User Notification Tool: 8.9.0.1023

Event Monitor Version: 8.9.0.1023

 

Array_0000

Status: No active migrations

Hard Drive Data Cache Enabled: Yes

Size: 931.5 GB

Free Space: 0 GB

Number of Hard Drives: 2

Hard Drive Member 1: ST500DM002-1BD142

Hard Drive Member 2: Missing hard drive

Number of Volumes: 1

Volume Member 1: Volume0

 

Volume0

Status: Degraded

System Volume: Yes

Volume Write-Back Cache Enabled: No

RAID Level: RAID 1 (mirroring)

Size: 465.7 GB

Physical Sector Size: 3072 Bytes

Logical Sector Size: 512 Bytes

Number of Hard Drives: 2

Hard Drive Member 1: ST500DM002-1BD142

Hard Drive Member 2: Missing hard drive

Parent Array: Array_0000

 

Hard Drive 0

Usage: Array member

Status: Normal

Device Port: 0

Device Port Location: Internal

Current Serial ATA Transfer Mode: Generation 2

Model: ST500DM002-1BD142

Serial Number: Z3TKN9YZ

Firmware: HP73

Native Command Queuing Support: Yes

Hard Drive Data Cache Enabled: Yes

Size: 465.7 GB

Physical Sector Size: 3072 Bytes

Logical Sector Size: 512 Bytes

Number of Volumes: 1

Volume Member 1: Volume0

Parent Array: Array_0000

 

Hard Drive 1

Usage: Non-RAID hard drive

Status: Normal

Device Port: 2

Device Port Location: Internal

Current Serial ATA Transfer Mode: Generation 2

Model: ST500DM002-1BD142

Serial Number: Z3TKKQQN

Firmware: HP73

Native Command Queuing Support: Yes

System Hard Drive: No

Size: 465.7 GB

Physical Sector Size: 3072 Bytes

Logical Sector Size: 512 Bytes

 

Hard Drive 2

Status: Missing

 

Unused Port 0

Device Port: 4

Device Port Location: External

 

CD/DVD Drive 0

Device Port: 1

Device Port Location: Internal

Current Serial ATA Transfer Mode: Generation 1

Model: hp      DVD-RAM GH40L

Serial Number: Data not reported

Firmware: RB0E

 

 

 

 

 

Thanks in advance for all help.

 

Terry